Saturday 29 September 2012

CAMERA NOT RUN [FILM TECHNOLOGY]




Camera not run  
[Film Technology] 

 

[1] Camera battery does not produce full voltage on load[poor connections between individual cells].

 

[2] Camera Battery fused or circuit breaker open.

 

[3] Not fully charged [insufficient time, charge current inadequate, mains voltage wrong].

 

[4] Battery not delivering full power due to cold.

 

[5] Battery to camera cable has internal fault.[flex to check.]

 

[6] Battery to camera cable too thin or too long for current.

 

[7] Battery self charge discharged due to excessive heat during storage.

 

[8] Camera buckle switch and camera trip switches not set.

 

[9] Camera not sufficiently winterized for cold conditions.

 

[10] Camera not switched on [more than one switch]

 

[11] Camera seized up or stiff [try inching by hand].

 

[12] Mains power supply voltage or frequency not correct for camera motor [if mains].

 

[13] Poor electric contact somewhere. [uses test meter to test voltage at motor].

 

[14] Camera electronic circuits faulty. [plug in spare boards if available.].








No comments: